TECHNICAL DATA :: |
|
PHYSICAL
PROPERTIES* |
MAXFLEX |
TEST
METHOD* |
| Cell
Structure |
Closed
Cell |
- |
| Density
lbs/ft3 (g/cm3) |
3-6
(0.048-0.096)** |
ASTM
D 1667 |
Thermal
Conductivity
BTU. in/ft 2 hr.°F (W/mK) |
Mean
Temp. |
-
4° F
( -20°C) |
32°
F
( 0°C) |
75°
F
( 24°C) |
90°
F
( 32°C) |
104°
F
(40°C) |
ASTM
C177
JIS A1412
DIN 52613
|
K-Value |
0.22
0.032 |
0.23
0.034 |
0.25
0.037 |
0.026
0.038 |
0.27
0.039 |
| Service
Temperature*** |
-
70°F to 257°F
- 57°C to 125°C
|
MAXFLAX
becomes hard at -57°C
but can be used even at -200°C |
| Water
Vapor Permeability (kg/Pa.s.m) |
0.10
perm-in (0.15 x 10-12) |
ASTM
C 355
ASTM E96 **** |
| Moisture
Resistance ( µ Value) |
µ
not less than 5000 |
DIN
52615 |
| Water
Absorption (weight %) |
not
more than 3% |
ASTM
D 1056 |
| Ozone
Resistance |
No
crack |
ASTM
D 1171 |
Heat
Stability (% shrinkage)
at 200°F and 220°F for 7 days |
4.5
and 5.5 respectively |
ASTM
C 534 |
| Flammability
& Smoke Density |
Class
VO |
Self-extinguishing |
Class
1 |
Class
0 |
Smoke
density 80 |
|
UL
- 94 |
ASTM
D 635 |
BS476
Part 7 1987 |
BS476
Part 6 1987 |
ASTM-E84
(15mm thick) |
|
| U.V.
Weather Resistance |
Excellent |
- |
| Nitrosamine
Contents |
Not
detected |
U.S.
FDA |
| Flexibility
|
Excellent |
- |
Note :
* Figure show average values obtained by the world well-knowm testing institues.
** Average density of insulation thickness over 20 mm.
*** At temp . under -57 °C MAXFLEX® HF becomes hard, but it doesn't attect themal conductivity nor water vapor permeability.
**** Water vapor permeability test was done under test method ASTM E96 dehydrate test method at 37.8 °C
|
PROPRIETA' FISICHE* |
MAXFLEX-HT |
METODO DI PROVA |
|
| MATERIALE |
EPDM GOMMA SINTETICA A BASE DI ETILENE, PROPILENE,DIENE MESCOLATI CON ADDITIVI |
|
|
| STRUTTURA |
CELLE COMPLETAMENTE CHIUSE |
|
|
| DENSITA' (g/cm3) |
0.048 0.080**
|
ASTM D 1667 |
PSB SINGAPORE |
CONDUCIBILITA'
TERMICA, (W/m.K) |
-20 'c |
0 'c |
24 'c |
32 'c |
4 0 'c |
ASTM C177
JIS A 1412
DIN 52613
|
IBP GERMANA |
0.031 |
0.033 |
0.036 |
0.037 |
0.038 |
| TEMPERATURA DI ESERCIZIO |
FINO A 150 'C SERVIZIO CONTINUO |
|
|
| FINO A 180 'C SERVIZIO INTERMITTENTE |
PERMEABILITA AL VAPOR D'ACQUA (kg/Pa.s.m)
|
0.10 perm-in (0.15x10 -12)
|
ASTM C 355
ASTM E96 |
PSB SINGAPORE |
| RESISTENZA ALLA UMIDITA |
µ NON INFERIORE A 10,000 |
DIN 52615 |
PSB SINGAPORE |
ASSORBIMENTO D'ACQUA
(% IN PESO) |
NON SUPERIORE AL 1.5% |
ASTM D 1056 |
|
| RESISTENZA ALL' OZONO |
NON PRESENTA FESSURAZION |
ASTM D 1171 |
PSB SINGAPORE |
RESISTENZA ALL'
INVECCHIAMENTO A 160'C |
NON PRESENTA FESSURAZION |
ASTM C 534 |
PSB SINGAPORE |
| RESISTENZA AI RAGGI UV |
NON PRESENTA FESSURAZION |
ISO 4892-2 |
PSB SINGAPORE |
STABILITA' AL CALORE
(% RITIRO IN PESO) A 95'C & 105'C PER 7 GIORNI |
3.5 & 4.5 |
ASTM C 534 |
PSB SINGAPORE |
| INFIAMMABILITA' & DENSITA' FUMI |
CLASSE VO |
UL-94 |
PSB SINGAPORE |
AUTOESTINGUENTE |
ASTM D635 |
PSB SINGAPORE |
CLASSE 1 |
BS 476 Part 7-1987 |
PSB SINGAPORE |
CLASSE 0 |
BS 476 Part 6-1987 |
PSB SINGAPORE |
CLASSE M1 |
AFNOR NF P92 501 |
CREPIMFRANCIA |
| CONTENUTO DI NITROSAMMINA |
NO |
BS EN 12868 |
PSB SINGAPORE |
| RESISTENZA A FUNGHI,MUFFE |
PASSA |
ASTM G21 |
PSB SINGAPORE |
| RIDUZIONE DEL RUMORE |
36.3 db |
DIN 52219 |
IBP |
| FLESSIBILITA' |
ECCELLENTE |
|
|
Note :
* VALORI MEDIATIOTTENUTI DA ENTI INTERNAZIONALI
** DENSITA & MEDIA PER SPESSORI SOPRA 20 mm.
|
PHYSICAL PROPERTIES* |
MAXFLEX® HF |
TEST METHOD* |
INSTITUTE |
| MATERIAL OF INSULATION |
SYNTHETIC ELASTERMERIC WITHOUT CHLORIDE AND BROMIDE IONS |
|
|
| CELL STRUCTURE |
COMPLETE CLOSED CELL |
- |
- |
| DENSITY lbs/ft3 (g/cm3) |
3 ~ 5 ( 0.048 ~ 0.080 ) |
ASTM D 1667 |
PSB Corp., SINGAPORE |
| THERMAL CONDUCTIVITY BTU.in/ft2 hr. °F (W/m.K) |
-4 °F
-20 °C |
32 °F
0 °C |
75 °F
24 °C |
90 °F
32 °C |
104 °F
40 °C |
ASTM C177
JIS A 1412
DIN 52613
|
FIW MUNCHEN, GERMANY |
0.22
0.031 |
0.23
0.033 |
0.25
0.036 |
0.26
0.037 |
0.27
0.038 |
| SERVICE TEMPERATURE ** |
-57 °C to 150 °C |
MAXFLEX® HF becomes hard at -57 °C but can be used even at -200 °C ** |
|
WATER VAPOR PERMEABILITY (kg/Pa.s.m) |
0.10 perm-in (0.15 x 10-12) |
ASTM C 355
ASTM E96 *** |
PSB Corp., SINGAPORE |
| MOISTURE RESISTANCE (µ Value) |
µ not less than10,000 |
DIN 52615 |
PSB Corp., SINGAPORE |
| WATER ABSORPTION (weight %) |
Not More Than 1.5% |
ASTM D 1056 |
PSB Corp., SINGAPORE |
| OZONE RESISTANCE |
Non crack |
ASTM D 1171 |
PSB Corp., SINGAPORE |
| HEAT STABILITY (% Shrinkage) at 200 °F and 220 °F for 7 days |
3.5 and 4.5 respectively |
ASTM C 534 |
PSB Corp., SINGAPORE |
| ULTRA - VIOLET RESISTANCE |
Non Crack |
ISO 4892-2 |
PSB Corp., SINGAPORE |
| FIRE PERFORMANCE |
Class VO |
UL - 94 |
PSB Corp., SINGAPORE |
Self-extinguishing |
ASTM D635 |
PSB Corp., SINGAPORE |
B2 |
DIN 4102 |
BODYCOTE, GERMANY |
| BEHAVIOR IN FIRE |
Self-extinguting, does not spread flame, does not drip |
- |
- |
| NITROSAMINE CONTENTS |
No Detect |
BS EN 12868 |
PSB Corp., SINGAPORE |
| FUNGUS RESISTANCE |
Passed |
ASTM G21 |
PSB Corp., SINGAPORE |
| RIDUZIONE DEL RUMORE |
36.3 db |
DIN 52219 |
IBP, GERMANY |
| FLEXIBILITY |
Excellent |
- |
- |
| STAINLESS STEEL AND COPPER CORROSION |
Negligible |
- |
- |
Note :
* Figure show average values obtained by the world well-knowm testing institues.
** At temp . under -57 °C MAXFLEX® HF becomes hard, but it doesn't attect themal conductivity nor water vapor permeability.
*** Water vapor permeability test was done under test method ASTM E96 dehydrate test method at 37.8 °C
|
PHYSICAL PROPERTIES* |
MAXFLEX® IsolOne |
TEST METHOD* |
INSTITUTE |
| MATERIAL OF INSULATION |
EDPM BLEND WITH ADDITIVE |
|
|
| CELL STRUCTURE |
COMPLETE CLOSED CELL |
- |
|
| DENSITY lbs/ft3 (g/cm3) |
3 ~ 5 ( 0.048 ~ 0.080 ) |
ASTM D 1667 |
PSB Corp., SINGAPORE |
| THERMAL CONDUCTIVITY BTU.in/ft2 hr. °F (W/m.K) |
-4 °F
-20 °C |
32 °F
0 °C |
75 °F
24 °C |
90 °F
32 °C |
104 °F
40 °C |
ASTM C177
JIS A 1412
DIN 52613
|
FIW MUNCHEN, GERMANY |
0.22
0.031 |
0.23
0.033 |
0.25
0.036 |
0.26
0.037 |
0.27
0.038 |
| SERVICE TEMPERATURE ** |
up to 150 °C operating continuous up to 180 °C operating intermitant |
MAXFLEX® HF becomes hard at -57 °C but can be used even at -200 °C ** |
|
WATER VAPOR PERMEABILITY (kg/Pa.s.m) |
0.10 perm-in (0.15 x 10-12) |
ASTM C 355
ASTM E96 *** |
PSB Corp., SINGAPORE |
| MOISTURE RESISTANCE (µ Value) |
µ not less than 10,000 |
DIN 52615 |
PSB Corp., SINGAPORE |
| WATER ABSORPTION (weight %) |
Not More Than 1.5% |
ASTM D 1056 |
PSB Corp., SINGAPORE |
| OZONE RESISTANCE |
Non crack |
ASTM D 1171 |
PSB Corp., SINGAPORE |
| AGING RESISTANCE AT 160 C. 150 hrs. |
Non crack |
ASTM 537 |
CERISIE, ITALY |
| ULTRA - VIOLET RESISTANCE |
Non Crack |
ISO 4892-2 |
CERISIE, ITALY |
| HEAT STABILITY (% Shrinkage) at 200 °F and 220 °F for 7 days |
3.5 and 4.5 respectively |
ASTM C 534 |
PSB Corp., SINGAPORE |
| FLAMMABILITY AND SMOKE DENSITY |
Class VO |
UL - 94 |
PSB Corp., SINGAPORE |
Self-extinguishing |
ASTM D635 |
PSB Corp., SINGAPORE |
Class 1 |
BS 476 Part 7 1987 |
PSB Corp., SINGAPORE |
Class 0 |
BS 476 Part 7 1987 |
PSB Corp., SINGAPORE |
Class M1 |
FRANCE AFNOR NF P92 501 |
CREPIM, FRANCE |
| NITROSAMINE CONTENTS |
No Detect |
BS EN 12868 |
PSB Corp., SINGAPORE |
| FUNGUS RESISTANCE |
Passed |
ASTM G21 |
PSB Corp., SINGAPORE |
| NOISE REDUCTION |
36.3 db |
DIN 52219 |
IBP, GERMANY |
| FLEXIBILITY |
Excellent |
- |
- |
Note :
* Figure show average values obtained by the world well-knowm testing institues.
** At temp . under -57 °C MAXFLEX® HF becomes hard, but it doesn't attect themal conductivity nor water vapor permeability.
*** Water vapor permeability test was done under test method ASTM E96 dehydrate test method at 37.8 °C
|
|
| |
|
| |
VANDAPAC
COMPANY LIMITED
93 Moo15 Watkingkaew Road, Bangpleeyai
Bangplee, Samutprakarn 10540, Thailand
Tel: 66-2312-4147-50, 2750-1560 Fax : 66-2312-4151
|
|
|
|
|